Wind Solar Hybrid System Controller


The wind solar hybrid system controller is used to control the wind power charging battery under constant voltage. In addition, it includes solar charging control, which makes it good for wind/solar hybrid application

Features

1.Manual brake 

2.Wind power indicate

3.Off-load indicate

 

Wind Solar Hybrid Street Lighting Controller

Technical Parameter

Model HC03-12  HC06-24
Max Wind Input Power 300W 600W
Max PV Input Power 100W 200W
Rated Battery Voltage 12VDC 24VDC
Floating Charge Voltage 14.5VDC 28VDC
Low Battery Voltage 11VDC 22VDC
Low Battery Recovery Voltage 12VDC 24VDC
DC Output two DC output,one controlled by light,one controlled by time
Max Output Power  120W for each DC output
Protection Type over voltage, low battery
pole-confusion protection automatic dump-load function.
Working Environment  Temperature -20~50℃,Altitude ≤4000m,Humidity 0~90%,no condensing
Size(W×H×D) single-phase 150*68*150mm,three-phase 190*68*150mm
Weight single-phase 0.8kg,three-phase 1.1kg

Wind Solar hybrid Generation System Controller

Technical Parameter

Model HC10-24 HC10-48 HC20-48  HC20-120 HC30-120  HC30-240
Max Wind Input Power 1KW 1KW 2KW 2KW 3KW 3KW
Max PV Input Power 300W 300W 600W 600W 900W 900W
Rated Battery Voltage 24VDC 48VDC 48VDC 120VDC 120VDC 240VDC
Floating Charge Voltage 28VDC 56VDC 56VDC 140VDC 140VDC 480VDC
Display Method LCD
Display Parameter Battery Voltage,Charging Current
Protection Type pole-confusion, automatic dump-load function.
Working Environment  Temperature -20~50℃,Altitude ≤4000m,Humidity 0~90%,no condensing
Size(W×H×D) 43*20*37cm 43*20*37cm 47*23*41cm 47*23*41cm 48*55*24cm 48*55*24cm
Weight 7.2kg 7.2kg 12kg 11kg 13.2kg 13.2kg
 
Model HC50-120  HC50-240 HC100-220  HC100-240 HC200-240  HC200-480
Max Wind Input Power 5KW 5KW 10KW 10KW 20KW 20KW
Max PV Input Power 1.5KW 1.5KW 3KW 3KW 6KW 6KW
Rated Battery Voltage 120VDC 240VDC 216VDC 240VDC 240VDC 480VDC
Floating Charge Voltage 140VDC 480VDC 252VDC 480VDC 480VDC 560VDC
Display Method LCD
Display Parameter Battery Voltage, Charging Current
Protection Type pole-confusion protection , automatic dump-load function.
Working Environment  Temperature -20~50℃,Altitude ≤4000m, Humidity 0~90%,no condensing
Size(W×H×D) Unload box 82*25*49cm                       Control box 44*21*38cm Unload box 60*89*60cm   Control box 44*21*38cm   Unload box 60*17*60cm    Control box 44*21*38cm
Weight  Unload box 25.5kg                   Control box 10kg Unload box 59kg              Control box10kg  Unload box 109kg                      Control box10kg