The wind solar hybrid system controller is used to control the wind power charging battery under constant voltage. In addition, it includes solar charging control, which makes it good for wind/solar hybrid application Features 1.Manual brake 2.Wind power indicate 3.Off-load indicate
Wind Solar Hybrid Street Lighting Controller
Technical Parameter
| Model | HC03-12 | HC06-24 |
| Rated Battery Voltage | 12V | 24V |
| Rated Wind Turbine Power | 300W | 600W |
| Wind Turbine Maximum Input Current | 40A | 40A |
| Wind Turbine Maximum Input Power | 500W | 1000W |
| Unload Voltage(factory default) | 14V | 28V |
| Unload Current(factory default) | 25A | 25A |
| PV Power | 150W | 300W |
| Battery Over-discharge Voltage Shutoff | 11V | 22V |
| Battery Over-discharge Recovery | 12V | 24V |
| Output Protection Voltage | 16V | 32V |
| PV Voltage Of Light-Control On | Adjustable(1V) | Adjustable(2V) |
| PV Voltage Of Light-Control Off | Adjustable(1.5V) | Adjustable(3V) |
| Line 1 Rated Output Current | 10A | 10A |
| Line 2 Rated Output Current | 10A | 10A |
| Line 1 Output Mode(Factory Default) | 3 Modes selection(Light-control on and Light-control off) | 3 Modes selection(Light-control on and Light-control off) |
| Line 2 Output Mode(Factory Default) | 3 Modes selection(Light-control on and time-control 5 hours) | 3 Modes selection(Light-control on and time-control 5 hours) |
| Control Mode | PWM | |
| Display Mode | LCD | |
| Display Parameters | Wind Turbine Power,Wind Turbine Voltage,Wind Turbine Current,PV Voltage、PV Charge Current,PV Power, Battery Voltage,Ove-Voltage,Under-Voltage, Over-load, short circuit.Etc | |
| Working Temperature &Humidity | -20~+55℃/35~85%RH(Without Condensation) | |
| Quiescent Current | 20±2 mA | |
| Protection Function | Solar reverse-charging protection , solar reverse-connection protection,battery over charge protection,battery over-discharge protection, battery reverse-connection protection, lightning protecting,wind turbine current limitting, wind turbine automatic brake and manual brake. | |
Wind Solar hybrid Generation System Controller
Technical Parameter
| Model | HC10-24 | HC10-48 | HC20-48 | HC20-96 | HC30-48 | HC30-96 |
| Max Wind Input Power | 1KW | 2KW | 3KW | |||
| Max PV Input Power | 300W | 600W | 900W | |||
| Rated Battery Voltage | 24VDC | 48VDC | 48VDC | 96VDC | 48VDC | 96VDC |
| Wind Turbine Maximum Input Current | 60A | 30A | 65A | 35A | 100 A | 50 A |
| Wind Turbine Maximum Input Power | 1.5kW | 3kW | 5kW | |||
| Unload Voltage(factory default) | 28VDC | 56VDC | 56VDC | 112VDC | 56VDC | 112VDC |
| Unload Current(factory default | 50A | 25A | 50A | 25A | 25 A | 25 A |
| Control Mode | PWM | |||||
| Display Mode | LCD | |||||
| Display Parameter | Wind Turbine Power,Wind Turbine Voltage,Wind Turbine Current,PV Voltage,PV Charge Current,PV,Power,Battery Voltage.Etc | |||||
| Protection Function | Solar reverse-charging protection,solar reverse-connection protection,battery over charge protection,battery over-discharge protection,battery reverse-connection protection, lightning protecting,wind turbine current limitting, wind turbine automatic brake and manual brake | |||||
| Working Environment | -20~+55℃/35~85%RH(Without Condensation) | |||||
| Model | HC50-48 | HC50-96 | HC100-120 | HC100-220 | HC200-220 | HC200-240 |
| Max Wind Input Power | 5KW | 10KW | 20KW | |||
| Max PV Input Power | 1.5KW | 3KW | 6KW | |||
| Rated Battery Voltage | 48VDC | 96VDC | 120VDC | 220VDC | 220VDC | 240VDC |
| Wind Turbine Maximum Input Current | 170A | 85A | 130A | 70A | 150A | 135A |
| Wind Turbine Maximum Input Power | 8KW | 15KW | 30KW | |||
| Unload Voltage(factory default) | 112VDC | 112VDC | 140VDC | 252VDC | 252VDC | 280VDC |
| Unload Current(factory default | 25 A | 25 A | 25 A | 25 A | 25 A | 25 A |
| Control Mode | PWM | |||||
| Display Mode | LCD | |||||
| Display Parameter | Wind Turbine Power,Wind Turbine Voltage,Wind Turbine Current,PV Voltage,PV Charge Current,PV,Power,Battery Voltage.Etc | |||||
| Protection Function | Solar reverse-charging protection,solar reverse-connection protection,battery over charge protection,battery over-discharge protection,battery reverse-connection protection, lightning protecting,wind turbine current limitting, wind turbine automatic brake and manual brake | |||||
| Working Environment | -20~+55℃/35~85%RH(Without Condensation) | |||||